Altronix

Altronix Controlador de energia para controlo de acessos (Maximal1RHDV)
Por encomenda
- EstadoNovo
- Garantia1 ano
- MarcaAltronix
- ReferênciaMaximal1RHDV
- CódigoSL-05559
- EntregaLuanda, combinada no pedido
Produtos relacionados
Altronix Controlador de energia para controlo de acessos (AL1012ACMCB220)Preço sob consulta
Altronix Controlador de energia para controlo de acessos (AL1024ACMCB220)Preço sob consulta
Altronix Controlador de energia para controlo de acessos (AL600ACMCB220)Preço sob consulta
Altronix Controlador de energia para controlo de acessos (eFlow102NA8DV)Preço sob consulta
Descrição
Access Power Controller w/ Power Supply/Charger, 8 PTC Relay Outputs, 12/24VDC @ 4A, 220VAC, 2U
Maximal1RHDV rack mount access power controller distributes and switches power to access control systems and accessories. It converts a 220VAC (working range 198VAC - 256VAC), 50/60Hz input into eight (8) independently controlled 12VDC or 24VDC PTC protected outputs. Outputs are activated by a normally open (NO) or normally closed (NC) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the outputs.
Ver mais informaçõesVer menos
Ficha técnica
- Modelo: Maximal1RHDV
- Entrada: 220VAC (working range 198VAC - 256VAC), 50/60Hz, 1.0A.; Normally closed [NC] or normally open [NO] dry contact inputs (switch selectable).
- Saídas: 12VDC @ 4A or 24VDC @ 3A total output current.; Eight (8) PTC protected outputs (auto-resettable).; Maximum current per ACM8R-M output is 2A.; Individually sele
- Interface de alarme de incêndio: Latching or Non-Latching fire alarm reset switch individually selectable for each output.; Remote reset capability for latching Fire Alarm Interface mode.
- Opções de entrada de corte do alarme de incêndio: a) Normally open [NO] or normally closed [NC] dry contact input.; b) Polarity reversal input from FACP signaling circuit.
- Indicadores visuais: Individual Output Status LEDs located on the front panel.
- Carregamento de bateria: Type: Sealed lead acid or gel type.; Failover: Upon AC loss, instantaneous.; (Batteries are sold separately).
- Supervision: AC fail supervision (form "C" contacts).; Notification trigger is selectable for 30 seconds (factory set) or 6 hours.; Low battery and battery presence supervis
- Características adicionais: Removable terminal blocks with locking screw flange.; 3-wire line cord.; Illuminated master power disconnect circuit breaker with manual reset.
- Temperatura: Operating: 0° C a 49° C (32° F a 120° F).; Storage: - 20° C a 70° C ( - 4° F a 158° F).; Relative Humidity: 85% +/- 5%.
- BTU/Hr. (approx.): 12VDC: 25 BTU/Hr.; 24VDC: 37 BTU/Hr.
- Dimensões: 486 mm W x 83 mm H x 216 mm D