Access Power Distribution Module w/ Power Supply/Charger, 5 PTC Class 2 Outputs, 12VDC @ 10A, FAI, 220VAC, BC400 Enclosure

Access Power Distribution Module w/ Power Supply/Charger, 5 PTC Class 2 Outputs, 12VDC @ 10A, FAI, 220VAC, BC400 Enclosure

AL1012M220 multi-output access control power supply/charger is specifically designed for use with access control systems and accessories. This unit converts a 220VAC 50/60Hz input into five (5) individual PTC protected 12VDC outputs (see specifications). Each output will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. These outputs will operate in both Fail-Safe and Fail-Secure modes. Controlled trigger input is achieved through normally open (N.O.) or normally closed (N.C.) supervised input or the polarity reversal from an FACP (Fire Alarm Control Panel). A form "C" dry output relay enables HVAC Shutdown, Elevator Recall or may be used to trigger auxiliary devices.

Ficha técnica

  • Modelo: AL1012M220
  • Input: Input 220VAC 50/60Hz, 2.2A.; Input fuse rated @ 5A/250V.; Fire Alarm Panel or Access Control System trigger inputs. N.O. or N.C. supervised trigger input and po
  • Output: 12VDC outputs.; 10A supply current.; Five (5) (auto-resettable) individual PTC protected outputs, rated @ 2A.; Output relay energizes when unit is triggered (fo
  • Battery Charging: Built-in charger for sealed lead acid or gel type batteries.; Automatic switch over to stand-by battery when AC fails (zero voltage drop).; (Batteries are sold
  • Supervision: AC fail supervision (form "C" contact).; Low battery supervision (form "C" contact).; Battery presence supervision (form "C" contact).; Power fail supervision r
  • Visual Indicators: DC output LED indicator.; LEDs indicate condition of power outputs.; Power & input trigger LEDs.
  • Temperature: Operating: 0° C to 49° C (32° F to 120° F).; Storage: - 20° C to 70° C ( - 4° F to 158° F).; Relative Humidity: 85% +/- 5%.; BTU/Hr. (approx.): 61 BTU/hr.; Syst
  • Dimensões: 310.6 mm W x 393.7 mm H x 114.3 mm D