Todas as categorias
Controlo de acessos
Altronix Access Power Distribution Module w/ Power Supply/Charger, 5 PTC Class 2 Outputs, 12/24VDC (AL600M220)

Altronix

Altronix Access Power Distribution Module w/ Power Supply/Charger, 5 PTC Class 2 Outputs, 12/24VDC (AL600M220)

Por encomenda

  • EstadoNovo
  • Garantia2 anos (fabricante)
  • MarcaAltronix
  • ReferênciaAL600M220
  • CódigoSL-04456
  • EntregaLuanda, combinada no pedido

Access Power Distribution Module w/ Power Supply/Charger, 5 PTC Class 2 Outputs, 12/24VDC @ 6A, FAI, 220VAC, BC300 Enclosure

Access Power Distribution Module w/ Power Supply/Charger, 5 PTC Class 2 Outputs, 12/24VDC @ 6A, FAI, 220VAC, BC300 Enclosure

AL600M220 is specifically designed for use with access control systems and accessories. This units converts a 220VAC / 60Hz input into five (5) individually PTC protected 12VDC or 24VDC outputs. Each output will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. These outputs will operate in both Fail-Safe and Fail-Secure modes. Controlled trigger input is achieved through normally open (N.O.) or normally closed (N.C.) supervised input or the polarity reversal from an FACP (Fire Alarm Control Panel). A form "C" dry output relay enables HVAC Shutdown, Elevator Recall or may be used to trigger auxiliary devices.

Ficha técnica

  • Modelo: AL600M220
  • Input: Input 220VAC / 60Hz, 1.5A.; Input fuse rated @ 3.5A/250V.; Fire Alarm Panel or Access Control System trigger inputs. N.O. or N.C. supervised trigger input and p
  • Output: 12VDC or 24VDC selectable outputs.; 6A supply current.; Five (5) (auto-resettable) PTC protected outputs, rated @ 2A.; Output relay energizes when unit is trigg
  • Battery Charging: Built-in charger for sealed lead acid or gel type batteries.; Automatic switch over to stand-by battery when AC fails.; (Batteries are sold separately).
  • Supervision: AC fail supervision (form "C" contacts).; Low battery supervision (form "C" contacts).; Battery presence supervision (form "C" contacts).; Power fail supervisio
  • Visual Indicators: AC input and DC output LED indicators (power supply board).; Red LEDs indicate condition of power outputs (multi-output board).; Power & input trigger LEDs (mul
  • Temperature: Operating: 0° C to 49° C (32° F to 120° F).; Storage: - 20° C to 70° C ( - 4° F to 158° F).; Relative Humidity: 85% +/- 5%.
  • BTU/Hr. (approx.): 12VDC: 37 BTU/Hr.; 24VDC: 74 BTU/Hr.; System AC input VA requirement: 176VA.
  • Dimensões: 317.5 mm W x 330.2 mm H x 82.6 mm D
Fale connosco