Altronix Access Power Controller w/ Power Supply/Chargers, Dual, 16 PTC Class 2 Relay Outputs, 1-24 (Maximal75FDV)
Por encomenda
- EstadoNovo
- Garantia2 anos (fabricante)
- MarcaAltronix
- ReferênciaMaximal75FDV
- CódigoSL-05631
- EntregaLuanda, combinada no pedido
Access Power Controller w/ Power Supply/Chargers, Dual, 16 PTC Class 2 Relay Outputs, 1-24VDC @ 9.7A, 1-12VDC @ 9.5A, FAI, LinQ2 Ready, 220VAC, BC800 Enclosure
Access Power Controller w/ Power Supply/Chargers, Dual, 16 PTC Class 2 Relay Outputs, 1-24VDC @ 9.7A, 1-12VDC @ 9.5A, FAI, LinQ2 Ready, 220VAC, BC800 Enclosure
Maximal75FDV Access Power Controller distributes and switches power to access control systems and accessories. It converts a 220VAC (working range 198VAC - 256VAC), 50/60Hz input into sixteen (16) independently controlled 12VDC and 24VDC PTC protected outputs. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/ or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs. All interconnecting equipment must be UL Listed.
Ficha técnica
- Modelo: Maximal75FDV
- Input: 220VAC (working range 198VAC - 256VAC), 50/60Hz, 4.8A input.
- Power supply input options: a) Two (2) common power input for either ACM8CB and lock power (factory installed).; b) Two (2) isolated power inputs (external power supply is required). Curre
- Input options: a) Sixteen (16) normally open (NO) inputs.; b) Sixteen (16) open collector inputs.; c) Any combination of the above.
- Output: 12VDC and 24VDC outputs.
- Maximum output current Options: A) 24VDC @ 9.6A plus 12VDC @ 9.3A.; Sixteen (16) independently controlled outputs can be Fail-Safe and/or Fail-Secure power outputs (auto-resettable).; Sixteen
- Power Supply input fuse ratings: eFlow104NBV - 6.3A/250V.; eFlow102NBV - 5A/250V.; ACM8CB boards main fuse is rated at 10A. PTC outputs are rated @ 2.5A each.
- Features: Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs.
- Fire Alarm disconnect input options: a) Normally open (NO) or normally closed (NC) dry contact input.; b) Polarity reversal input from FACP signaling circuit.; Alarm output relay indicates that FAC
- Supervision: AC fail supervision (form "C" contacts).; Notification trigger is selectable for 30 seconds (factory set) or 2 hours.; Low battery and battery presence supervis
- Battery Charging: Capacity: 12AH/12VDC (4 within enclosure); 40AH/65AH (requires separate enclosure).; Type: Sealed lead acid or gel type.; Failover: Upon AC loss, instantaneous.
- Visual Indicators: Red LEDs indicate outputs are triggered (relays energized).; Green LED indicates FACP disconnect is triggered.; AC input and DC output LED indicators.
- Temperature: Operating: 0° C to 49° C (32° F to 120° F).; Storage: - 20° C to 70° C ( - 4° F to 158° F).; Relative Humidity: 85% +/- 5%.; BTU/Hr. (approx.): 177 BTU/Hr.; Sys
- Dimensões: 483 mm W x 660.4 mm H x 159 mm D