Access Power Controller w/ Power Supply/Charger, 16 Fused Relay Outputs, 12/24VDC @ 6A, 220VAC, 2U
Access Power Controller w/ Power Supply/Charger, 16 Fused Relay Outputs, 12/24VDC @ 6A, 220VAC, 2U
Maximal3RV rack mount access power controller distributes and switches power to access control systems and accessories. It converts a 220VAC (working range 198VAC - 256VAC), 50/60Hz input into sixteen (16) independently controlled 12VDC or 24VDC fuse protected outputs. Outputs are activated by an normally open (NO) or normally closed (NC) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the outputs.
Ficha técnica
- Modelo: Maximal3RV
- Input: 220VAC (working range 198VAC - 256VAC), 50/60Hz, 1.0A.; Normally closed [NC] or normally open [NO] dry contact inputs (switch selectable).
- Outputs: 12VDC or 24VDC @ 6A total output current.; Sixteen (16) fuse protected outputs.; Maximum current per ACM8R-M output is 2.5A.; Individually selectable Mag Lock/S
- Fire Alarm Interface: Latching or Non-Latching fire alarm reset switch individually selectable for each output.; Remote reset capability for latching Fire Alarm Interface mode.
- Fire Alarm disconnect input options: a) Normally open [NO] or normally closed [NC] dry contact input.; b) Polarity reversal input from FACP signaling circuit.
- Visual Indicators: Individual Output Status LEDs located on the front panel.
- Battery Charging: Type: Sealed lead acid or gel type.; Failover: Upon AC loss, instantaneous.; (Batteries are sold separately).
- Supervision: AC fail supervision (form "C" contacts).; Notification trigger is selectable for 30 seconds (factory set) or 6 hours.; Low battery and battery presence supervis
- Additional Features: Removable terminal blocks with locking screw flange.; 3-wire line cord.; Illuminated master power disconnect circuit breaker with manual reset.
- Temperature: Operating: 0° C to 49° C (32° F to 120° F).; Storage: - 20° C to 70° C ( - 4° F to 158° F).; Relative Humidity: 85% +/- 5%.
- BTU/Hr. (approx.): 12VDC: 37 BTU/Hr.; 24VDC: 74 BTU/Hr.
- Dimensões: 486 mm W x 83 mm H x 216 mm D